MODULAR STORAGE TANKS THAT RELOCATE AND SCALE
Adaptability
Water balances shift, footprints tighten, and a project that starts at one volume rarely finishes there. Concept Tanks engineers modular storage to adapt with the project: diameter and wall height are set independently, capacity can be added or removed using existing components, and the system relocates when the project moves on.
Earthen dams commit an operator to one capacity, one footprint and one site. Concept Tanks has installed more than 400 modular systems across Australia and North America as the alternative.
Relocatable
Solution
Containment investment should move with the project. Every Concept Tank™ and Concept AST™ (Above-ground Steel Tank) is engineered to demobilise and redeploy, so the asset is reused rather than written off. Because each system sits on a compacted earthen pad rather than a concrete slab, site remediation at demobilisation is significantly reduced.
For drilling programs, staged mine developments and remediation campaigns, the Concept Tank™ can follow the project across multiple sites over its 25-year structural design life.

*table to be used as a guide only
Constrained Footprint
Where the site dictates the shape, the system adapts. The Concept Tank™'s patented modular design allows the diameter and wall height to be varied independently, meeting a precise volume target within an irregular or tight footprint or alongside existing infrastructure.
The Concept Tank™ spans diameters from 20 m to 175 m, with wall height configured to the project.
The Concept AST™ is a temporary storage system with a fixed diameter, configurable by wall height. A 70 m diameter system holds 9.8 megalitres (ML) at 2.4 m wall height, or 14.5 ML at 3.7m.
Our engineers design the panel height, diameter, and wall thickness to match site constraints, specific gravity, and storage volume. The inverted conical earthen base minimises earthworks.
Incremental Build
Over-building against uncertain demand front-loads capital before a project has proven itself; under-building constrains it. A Concept Tank™ is sized to current requirements and grows with the operation, reconfiguring larger or smaller using existing components. Multi-tank arrangements scale beyond 200 ML, with additional systems installed as volumes grow rather than at the outset.
Engineered Floating Covers, supervisory control and data acquisition (SCADA) integration and remote monitoring, anti-climb protection, viewing platforms, overflow weirs and bird netting can be retrofitted as requirements change.
See also: Mining, Oil & Gas, Rapid Deployment, Engineering and Asset Services ↗

Rent. Buy.
Rent with a Buy-out Option.
Adaptability extends to the commercial structure. Rental, purchase and long-term rental with a buy-out option align capital expenditure with project cash flows and budget cycles. The Concept AST™ (Above-ground Steel Tank) is available to buy, rent, or rent with a buy-out option. The Concept Tank™ is available to buy, as a long-term rental, or as a long-term rental with a buy-out option. The Concept Utility Tank™ is purchase only.
See also: Ways We Work With You ↗
Which tank suits your project
Provide the required volume, fluid type, site conditions and target operational date to receive a tailored recommendation.
|
Concept AST™
|
Concept Tank™
|
Concept Utility Tank™
|
|
| Capacity per tank | 0.6 to 14.5 ML | 1 to 78 ML | 12 to 70 ML |
| Structural design life | Up to 5 years, subject to condition | 25-years+ | Up to 100 years |
| Build Time | 1 to 6 days | 1 to 7 weeks | 3 to 4 months |
| Relocatable | Yes | Yes | No |
| Reconfigurable Diameter | No, fixed diameter | Yes, using existing panels | No |
| Best for | Emergency response, short campaigns | Larger volumes on expedited programs | Permanent storage on constrained sites |
Fluids we contain
Every system in the range stores fluids up to specific gravity (SG) 1.2 as standard, with higher SG available on request. Liner specifications are matched to fluid chemistry and asset service life.
- Leachate
- Produced water
- Brine
- Mine-affected water
- Industrial process fluids
- Data centre cooling and fire water
- PFAS-affected water
- Potable water
- Raw water
- Stormwater
- Dust suppression water
Proven in the field
Adaptability is demonstrated after installation: systems resized to a shifting water balance, relocated with the project, or extended as demand outgrew the original design. The project below shows an asset delivering value well beyond its commissioned scope.
Scalable Brine Evaporation
An oil & gas customer experienced rapid operational growth and increasing volumes of environmentally sensitive brine, necessitating secure storage and evaporation. Unclear total storage requirements resulted in planning uncertainty. An existing dam provided...
Rapid Remediation Fluid Storage
Remediation runs on a simple sequence. Treating contaminated earth includes treating contaminated groundwater. You can’t start treating contaminated groundwater without suitable storage. Storage sits on the critical path of remediation projects where downstream...
Pilbara Dust Suppression Storage
The Pilbara presented a relentless construction environment: mini-tornado whirlwinds, oppressive heat, strong winds, cyclone alerts, and high-UV exposure throughout the program. Iron ore dust, nicknamed the "Pilbara Fog", blanketed the zone continuously, intensified...
Frequently asked
questions
Can a system be resized after it is installed?
Yes. The Concept Tank™ is reconfigured larger or smaller using its existing precast panels and post-tensioned cable system, without major capital spend. Concept AST™ are relocatable but generally cannot change diameter.
What does relocation involve?
Demobilisation, transport and reinstallation on a new compacted earthen pad. A Concept AST™ reinstalls in 1–6 days after pad preparation; a Concept Tank™ in 1–7 weeks. They leave the original site as compacted ground.
What happens to the system at the end of the project?
It moves to the next project, returns at the end of a rental arrangement, or stays as a permanent asset. No reinstatement liability and no regret spend.
Configure. Relocate. Reuse.
Let us know how the project might change, and we'll engineer storage that changes with it.