LOW FOOTPRINT INDUSTRIAL WATER STORAGE

The Concept Utility Tank™

12 ML–70 ML per system | 50-year design life | Lined precast concrete construction

The Concept Utility Tank™ is a permanent above-ground industrial water storage tank built from lined precast concrete panels, with capacity up to 70 ML per system.
Designed for a 100-year service life, it suits operations requiring secure storage over decades. It stores raw water through to regulated process liquors, delivering reservoir-scale capacity with minimal earthworks.
The Concept Utility Tank™ delivers Containment Certainty across water utilities, mining, industrial and data centre sites.

Built for scale and permanence

Internally tensioned precast concrete high-wall panels form the structure, providing the durability required for large-scale, long-term fluid storage. With up to 70 ML per system, it suits sites needing substantial storage in a single structure rather than multiple smaller tanks.

Each system pairs the precast structure with a geomembrane liner system specified to the fluid chemistry and service life. The structure carries the load for the life of the asset, and the liner may be replaced on a planned cycle by the Concept Tanks liner team. Higher-specification liners are managed on condition and can last 30+ years.

Above-ground precast construction reduces the containment and approval risks associated with in-ground reservoirs, particularly on sites with elevated groundwater, sensitive receiving environments or strict licence conditions.

P CUT 01
P CUT 02

Where the Concept Utility Tank™ fits

In-ground reservoirs and earthen dams involve lengthy approvals, significant construction and costly rehabilitation, with a footprint and volume fixed from excavation.

For sites where storage is a permanent requirement, the Concept Utility Tank™ provides fixed infrastructure without those constraints.

Containment Certainty: End-to-end liner control and Leak Detection System

In-ground liners are difficult and costly to replace in situ. Above-ground installation makes relining a planned activity for the Concept Tanks liner crew, and keeps the system accessible for clean-outs and desludging.

Concept Tanks designs, fabricates, installs and QA-tests every liner in-house under its own quality assurance (QA) regime, with no third-party installers. The full liner surface is spark-tested on every installation, seam samples are taken for destructive testing, and repairs are validated on calibrated in-house equipment.

The dual-liner configuration enables the Leak Detection System (LDS), which monitors the interstitial space between the primary and secondary liners. A primary liner breach is identified before fluid reaches the ground.

 

P CUT 03

Fluids and Application

The Concept Utility Tank™ stores regulated and industrial liquids across eight major sectors:

Raw and Water Supply Storage

Per- and polyfluoroalkyl substances (PFAS)-affected water

Containment with a liner specified to the fluid chemistry

Potable Water Storage

Municipal and remote site storage

Data Centre Water

Permanent cooling water supply and fire water storage

Reverse Osmosis (RO) Brine

Long-term storage ahead of disposal or further treatment

Process effluent and process liquor

Regulated industrial and mining fluids

Storm Water

Capture and retention on constrained sites

Produced water

Permanent storage for established gas fields

Best for

01 1

High volume requirements

up to 70 ML per system

02

Footprint restrictions

low-diameter, high-walled storage and high capacity

03

Critical longevity

Up to 100-year design life for permanent or long-duration infrastructure decisions

04

Complex or varied fluids

From raw and potable water through to brine, produced water, PFAS and process liquor

05

Containment Assurance

geomembrane liner system for secure, long-term retention

06

High Compliance Exposure

dual liner system with end-to-end control, integrated leak detection system

The Concept Range

Concept AST™ Concept Tank™  Concept Utility Tank™
Best for Short- to medium-term, emergency and rental storage  Large, regulated storage that may grow, shrink or move  Permanent, high-capacity storage on a tight footprint 
Capacity per system  0.6 ML–14.5 ML  1 ML–78 ML (200 ML+ multi-tank)  12 ML–70ML
Structure  Bolted steel panels  Precast concrete panels on steel posts  Lined precast concrete panels 
Construction time (after site prep)  1–6 days  1–7 weeks  3–4 months 
Structure design life  Up to 5 years, on condition  25-years+ Up to 100 years
Foundation  Earthen pad, ≥100kPa  Earthen pad Concrete ring beam 
Specific gravity  Up to 1.2 (higher on request)  Up to 1.2 (higher on request) Up to 1.2 (higher on request)
Relocatable Yes Yes No
Leak Detection System  Standard  Standard  Standard 
Solution pathway  Rapid Deployment, Adaptability  Adaptability, Rapid Deployment, Compliance Assurance  Compliance Assurance 

Technical Specification

Capacity12 ML–70 ML per system
StructureInternally tensioned precast concrete high-wall panels
LinerDual geomembrane liner with conductive geotextile and Leak Detection System as standard, specified to the fluid
Structure design lifeUp to 100 years
Liner design life20 years (conditional pro rata manufacturer's warranty); relined over the life of the system
Build time3–4 months after site preparation
Construction methodPrecast concrete panels erected on a concrete ring beam; liner installed and QA tested by Concept Tanks' in-house team
Specific gravityUp to 1.2 (higher on request)
FoundationConcrete ring beam
Wind loadRegional wind speed compliant
Design standardsSee Compliance Assurance ↗
Liner QA and testingAir lance seam testing; destructive seam sampling; vacuum box testing of extrusion welds; full-surface spark testing. Hydrostatic testing available on request.
RelocatableNo

Configuration Option

  • Leak Detection SystemSTANDARD
  • Custom PipeworkSTANDARD
  • BallastSTANDARD
  • SCADA System/Remote MonitoringADD - ON
  • Engineered Floating CoverADD - ON
  • Viewing PlatformADD - ON
  • Overflow WeirADD - ON
  • Bird NettingADD - ON
  • Anti-climb ProtectionADD - ON

Proven in the field

Since 2009, Concept Tanks has installed 400+ systems across Australia and North America. The Concept Utility Tank™ is the permanent end of that range. It uses the same lined-panel engineering and in-house liner QA specified for sites where the storage decision is made once and lived with for decades.

Two Concept Utility Tank™ on and Industrial site.

Urban High-Capacity Storage

The customer faced three significant challenges in this project. The site offered minimal working area outside the designated pad, so traditional construction equipment, such as large machines and trucks, could not be accommodated. This spatial limitation posed a...

read more
The construction of a Concept Utility Tank™ for potable water storage.

Utility-Grade Government Containment

Remote sites make everything harder, and potable water leaves no margin for error. Our customer, an Australian water utility, needed two large-scale potable water storage systems at a remote site. The usual options didn’t stack up. Traditional storage was expensive...

read more

Frequently asked
questions

Common questions about the Concept Tank, Utility Tank, and Concept AST range. 

How long does a concrete water storage system last?

The Concept Utility Tank™ is engineered for a design life of up to 100 years. The precast concrete structure carries the load for the life of the asset, while the geomembrane liner provides containment and is specified to the stored fluid. The liner has a 20-year design life and is replaced over the life of the system. That makes it suited to infrastructure decisions with a multi-decade horizon rather than project-length ones.

How large can a single Concept Utility Tank™ be?

Up to 70 ML in a single system. For sites that need more, multiple Concept Utility Tanks™ can be installed on the same footprint. Capacity, diameter and wall height are set at the design stage to suit the site, the fluid and any airspace or footprint constraints.

What fluids can the Concept Utility Tank™ hold?

Raw, potable, storm and emergency water, RO brine, produced water, process effluent, PFAS and process liquor. The geomembrane liner is selected for the chemistry of the stored fluid, so regulated and complex liquors are contained with the same certainty as raw water.

Can the Concept Utility Tank™ be relocated?

No, and that is by design. The Concept Utility Tank™ is permanent infrastructure built for a 100-year design life. If your storage requirement is likely to move, grow or reduce, the Concept Tank™ or Concept AST™ is the better fit, and we will tell you so at the first conversation.

Is leak detection included?

Yes. A Leak Detection System is standard on every Concept Utility Tank™, providing proactive monitoring for early detection of potential containment issues so that a problem is found and dealt with long before it becomes an environmental or compliance event. 

Discuss your requirements

The Concept Utility Tank™ delivers secure, large-scale fluid storage engineered for a 100-year design life. Suited to raw water, stormwater, brine, produced water, potable water, emergency storage, process effluent, PFAS and process liquor.
If you are evaluating industrial water storage tanks for a permanent installation, talk to the team about your site, your fluid and your volume. Solving tomorrow's problems, today.