Low-footprint Fluid Storage for Australia's Industrials
Engineered, high-capacity storage for complex industrial fluids, with site-specific tank, liner and containment configurations for operating, brownfield and remediation sites.
15+
YEARS OF CONTAINMENT EXPERIENCE
up to 78ML
CAPACITY PER
SYSTEM
up to 100-year
STRUCTURE
DESIGN LIFE
Built for Complex Industrial Fluids
Industrial fluid streams vary widely in chemistry, temperature, volume and environmental risk. They range from process water and effluent to contaminated stormwater and remediation fluids.
Concept Tanks combines in-house engineering, tailored liner systems and large-scale modular storage. We engineer each system to your operation and the site footprint you have.
What heavy industrial operators
are facing
Complex fluid chemistry
Process liquor rarely behaves like water. pH, salinity, dissolved contaminants and temperature all affect liner performance, and a specification suited to one fluid can fail on the next. Concept Tanks engineers each system around the site and fluid, with the liner system selected to match.
Containment and compliance assurance
Regulated fluids carry licence conditions that operators must demonstrate they are meeting. Concept Tanks engineered above-ground storage includes an integrated Leak Detection System (LDS) that identifies a compromised liner before fluid reaches grade. Full quality assurance and quality control (QA/QC across manufacture, installation and commissioning establishes the audit trail from day one.
High-volume storage on constrained sites
Industrial sites rarely have spare land, and a dam's sloping batters consume footprint most sites cannot provide. The Concept Utility Tank™ delivers up to 70 ML of permanent storage within a significantly smaller footprint. Similarly, A Concept Tank™ can provide up to 78ML for larger diameter applications.
Rainfall ingress and evaporation
Storm events add volume that must be stored or treated, and open surfaces collect windborne site contaminants. A Concept Tanks Engineered Floating Cover (EFC) excludes rainfall and contaminants, with evaporation managed to suit site processes.
Brownfield and remediation work
Remediation proceeds in stages, and storage sized for stage one rarely suits stage three, leaving fixed infrastructure stranded. A modular Concept Tank™ can be resized, relocated, reused or repurposed as site requirements change.
Concept Tanks' Industrial applications
Industrial sites typically store multiple fluid types. Concept Tanks systems store fluids up to specific gravity (SG) 1.2, with higher SG available on request and the liner system specified to the fluid at design stage.
Chemical and heavy process plants
Industrial effluent buffering, process and cooling water storage, and interim containment for complex fluids, preventing upstream surges from overloading downstream treatment
Contaminated Lands and Site Remediation
Remediating legacy contaminated sites generates extracted groundwater, excavation dewatering and stormwater that has contacted contaminated soils, all of which must be contained ahead of treatment.
Dust Suppression
Bulk materials handling, stockpiles, haul roads and ports rely on a reliable water supply for dust suppression, particularly through dry periods when demand peaks and supply is weakest.
Smelting and metals processing
Storage of high-salinity, acidic and process-affected water ahead of treatment, with the liner system matched to the measured water chemistry.
Refining and fuel terminals
Fire water, process water buffering, trade waste and contaminated stormwater storage. Stormwater is typically the hardest to plan for, as volumes arrive with weather events rather than process schedules.
Food and bio-processing
Storage and balancing of high-strength trade waste ahead of treatment or discharge, with an Engineered Floating Cover (EFC) available to exclude rainfall and reduce evaporation.

Systems and add-ons at a glance
A quick comparison of the system configurations proposed for potable, network and environmental water storage, helping operators match the right storage approach to their site requirements.
|
Concept Tank™
Explore the Concept Tank™ ↗ |
Concept Utility Tank™
Explore the Concept Utility Tank™↗ |
Concept AST™
Explore the Concept AST↗ |
|
| Capacity | 1ML – 78ML | 12ML – 70ML | 0.6ML – 14.5ML |
| Best For | Large, regulated storage that may grow, shrink or move | Permanent, high-capacity storage on a tight footprint | Short- to medium-term, emergency and rental storage |
Add-Ons
EFC
Engineered Floating Cover
Engineered geosynthetic barrier used to prevent ingress of rain, cross contamination and prevent evaporation. We engineer and configure covers to your need to prevent excess generation and/or evaporation.
LDS
Leak Detection System
Monitors the interstitial void between primary and secondary liners, giving early warning of a potential primary-liner breach. Powered using a solar battery backup or mains power connection, our LDS services any site no matter how remote.
MONITORING
Remote Monitoring
Remote monitoring connects the system and LDS to your site supervisory control and data acquisition (SCADA) system or telemetry for remote visibility and alarm response.
PIPEWORK
Custom Pipework
Connecting the storage solution to your infrastructure pipework is configured to your needs, including under, over, or through wall penetrations, as well as flanges, valves and vortex breakers.
Proven performance
Industrial fluids are where our liner QA earns its keep. Every system is specified to the fluid and dual-lined with leak detection. It's handed over with the QA records a regulator asks for. Modular and relocatable options support permanent installations, brownfield sites and staged remediation programs as operational requirements change.
Rapid Remediation Fluid Storage
Remediation runs on a simple sequence. Treating contaminated earth includes treating contaminated groundwater. You can’t start treating contaminated groundwater without suitable storage. Storage sits on the critical path of remediation projects where downstream...
Queensland Industrial Stormwater Storage
Our heavy industrial customer needed containment for potential overland flow and stormwater, which increased the risk of containment failure because of its proximity to waterways and port facilities. The unlined dam risked seepage and lacked surge capacity during high...
Frequently asked
questions
Common questions about the Concept Tank, Utility Tank, and Concept AST range.
What specific gravity can your systems store?
Up to SG 1.2 as standard, with higher SG on request. The liner system is specified to the fluid at the design stage.
Can we get high-volume storage on a tight site?
Yes. A Concept Utility Tank™ gives you up to 70ML of permanent storage on a far tighter footprint than a dam with sloping sides.
Can storage move with a staged remediation program?
Yes. A modular Concept Tank™ can be resized, relocated, reused or repurposed as the site changes.
How do we prove containment to a regulator?
Every system carries a Leak Detection System as standard, and full QA/QC runs through manufacture, installation and commissioning, so the audit trail exists from day one.
Need an industrial fluid
storage solution?
Talk to our team about your fluid characteristics, required capacity, site footprint and operational requirements. We can help determine the appropriate system, liner and ancillary configuration for your industrial application.