ENGINEERED STORAGE FOR REGULATED SITES

Compliance Assurance

Regulated fluids carry licence conditions, and operators must be able to demonstrate compliance. Concept Tanks builds industrial fluid storage with the evidence in place before an auditor asks: a liner matched to the fluid, a Leak Detection System (LDS) as standard, and a quality assurance (QA) record from factory to commissioning. 
Earthen dams involve lengthy approvals, containment uncertainty and ongoing monitoring obligations. Concept Tanks has installed more than 400 above-ground systems across Australia and North America as the alternative.

Environmental Compliance

A high water table, an adjacent waterway or a zero-discharge licence can make in-ground storage a liability.

Above-ground storage requires a pad, not a pit: no excavation into the water table, no groundwater uplift pressure on the liner, and significantly less to reinstate at closure. Every Concept Tank™, Concept AST™ (Above-ground Steel Tank) and Concept Utility Tank™ uses a multi-layer geomembrane liner specified to the fluid chemistry.

A dual geomembrane configuration enables the LDS, with a conductive geotextile that protects the liner and enables full-surface spark testing. Where rainfall would otherwise become leachate, an Engineered Floating Cover excludes it and reduces odour emissions.

C 02
C 03

Regulatory Approvals

Earthen dam approvals can take longer than construction, and older ponds often lack the records assessors expect. A system on a compacted earthen pad presents a smaller approval scope with fewer conditions. Every system is designed to Australian standards for structural actions, regional wind loads, and the supporting earthworks.

 

Steel and concrete systems are engineered in accordance with applicable structural and liquid-retaining requirements.

 

Every system is handed over with the documentation regulators require:

  • Signed structural design certificate, referencing applicable standards and drawings
  • Liner QA records
  • As-built drawings
  • Quality assurance and quality control (QA/QC) records for manufacture, installation and commissioning

Evidence is in place ahead of any licence review.

Liner Quality Assurance

Liner performance depends on the QA regime applied at installation.
Concept Tanks designs, fabricates, installs and QA-tests its liner systems in-house, with no handover between trades. Every installation follows the same regime on calibrated in-house equipment:

    • Air-lance seam testing
    • Destructive seam sampling
    • Vacuum box testing
    • Full-surface spark testing
    • Hydrostatic testing on request

The liner integrates with the LDS, standard on every system. Optional solar- or mains-powered remote telemetry identifies a primary liner breach before any release to ground. The liner has a 20-year design life, a conditional pro rata warranty, and can be replaced in place.

Which tank suits your project

Send us the volume, fluid, site conditions and the date you need it operational.

Concept AST™
Concept Tank™
Concept Utility Tank™
Capacity per tank 0.6 to 14.5 ML  1 to 78 ML  12 to 70 ML 
Structural design life  Up to 5 years, subject to condition  25-years+ Up to 100 years
Install Time 1 to 6 days  1 to 7 weeks  3 to 4 months 
Relocatable  Yes Yes No
Leak Detection 
System  Standard | Visual Leak Detection System available Standard  Standard 
Designed to  All relevant Australian Standards All relevant Australian Standards All relevant Australian Standards
Best for  Interim compliance capacity, 
licence deadlines  Regulated fluids at volume,
sensitive sites  Permanent storage under
long-term licence 

Fluids we contain

Every system in the range stores fluids up to specific gravity (SG) 1.2 as standard, with higher SG available on request. Liner specifications are matched to fluid chemistry and asset service life.

  • Leachate
  • Produced water
  • Brine
  • Mine-affected water
  • Industrial process fluids
  • Data centre cooling and fire water
  • PFAS-affected water
  • Potable water
  • Raw water
  • Stormwater
  • Dust suppression water

Proven in the field

Since 2009, Concept Tanks has installed more than 400 systems across Australia and North America, each with the same engineered liner system, in-house QA regime and LDS as standard. Whether storing a regulated fluid for one season or thirty years, every system is handed over with the same QA file.

Two Concept Utility Tank™ on and Industrial site.

Urban High-Capacity Storage

The customer faced three significant challenges in this project. The site offered minimal working area outside the designated pad, so traditional construction equipment, such as large machines and trucks, could not be accommodated. This spatial limitation posed a...

read more
Concept AST™ in an urban industrial environment.

Rapid Remediation Fluid Storage

Remediation runs on a simple sequence. Treating contaminated earth includes treating contaminated groundwater. You can’t start treating contaminated groundwater without suitable storage. Storage sits on the critical path of remediation projects where downstream...

read more
The construction of a Concept Utility Tank™ for potable water storage.

Utility-Grade Government Containment

Remote sites make everything harder, and potable water leaves no margin for error. Our customer, an Australian water utility, needed two large-scale potable water storage systems at a remote site. The usual options didn’t stack up. Traditional storage was expensive...

read more

Frequently asked
questions

What happens if the Leak Detection System registers a breach?

With remote telemetry added, it reports straight away, so the breach is found before fluid reaches the ground, and the in-house team validates the repair to the same regime.

What testing is carried out on the liner?

Material QA, seam testing, destructive sampling and full-surface spark testing by our own technicians.

Contain. Test. Verify

Let us know what your licence requires, and we'll engineer the containment that proves it.