Our heavy industrial customer needed containment for potential overland flow and stormwater, which increased the risk of containment failure because of its proximity to waterways and port facilities. The unlined dam risked seepage and lacked surge capacity during high rainfall or equipment failures, increasing the likelihood of overflows and regulatory non-compliance.
In this sensitive location, incidents could jeopardise the operator’s licence and cause environmental and reputational damage. The system had to handle high flows, demanding robust hydraulic design. Mudflat ground threatened structural stability without proper foundations.
Solutions
Concept Tanks supplied two 8.5 megalitre precast concrete tanks with dual liner systems (conductive geotextile and cushioning layers) for rigorous QA testing, seepage prevention, and leak detection, recycling any leakage back into the tank. Custom pipework managed high flows, supported by a large thrust block to counter destabilising forces from substantial pipe sizes and an energy dissipator at the inlet to reduce water velocity, protecting liner integrity. A concrete ring beam foundation ensures stability on mudflats.
Outcomes
The solution provides increased storage, overflow protection, and regulatory compliance near sensitive areas. As of 2025, the tanks are fully operational for stormwater and emergency containment. Operators praise reliability, ease of integration, and environmental confidence.
Thrust blocks and dissipators effectively manage flows, preserving liner and structural performance. This project showcases Concept Tanks’ capability for high-flow applications on mudflat sites in high-risk environments, offering a template for similar refining operations.